APN - Access Parcel Number informational only Zoning - Use zone per City of San Jose Zoning Ordinance. For lots having a null value, it will require a manual look up Historic - If populated, the review process will be added at intake status. For boundary lots having a null value, it will require manual look up RDA Jurisdiction? - Determines whether Planning Department or Redevelopment Agency administer the planning permit Annexation Date - The date when the property as annexed to San Jose Tract # - Tract number will trigger Public Works Development clearance process if the number is listed in the PW database Lot # - Lot number for information only Building Inspection Area - The area allows first cut determination inspection scheduling and distribution Map Coordinates - For information only, the value will print on inspection slips Council District - Council district number and it also determines general ledger distribution of construction tax GeoHazard Zone - If populated, the review process will be added at intake status Flood Zone - If populated, the review process will be added at intake status School District - This infoield displays both high school and elementary school district in a single field Central Incentive Zone - Central Incentive Zone – Yes enacts exemption. For MF folder only. Expired on 01/01/2002 Inspecting Fire Station - Inspecting Fire Station number for informational only Distance to type A fault - Distance to seismic source type described in California Building Code Table 16-U Distance to type B fault - Distance to seismic source type described in California Building Code Table 16-U Road Noise - Road Noise - If populated, the “Traffic Noise Analysis” review process will be added to the folder Airport Noise - Airport Noise – If populated, the “Traffic Noise Analysis” review process will be added to the folder Ground Floor Use Restriction - If populated, the review process will be added at intake status into the multifamily and commercial / industrial folders Seismic Hazards - If populated, the review process will be added at intake status and charge an additional plan review fee Redevelopment Project Area - Planning Project Manager - For Planning folders only, Planning Project Manager Code Inspector - Name of inspector from Code Enforcement Neighborhood Organization - Neighborhood Organization Planning Project Manager - For building folder only, this infofield displays the name of project manager from Planning assigned to the area the property is located in Williamson Contract - Annexation Name - Annexation Number - Near Lightrail Station - Near County Park/Trail - Near Major Arterial/Collector - Near the Greenline - SNI Area - Parking Management Zone - Alcohol Sales Restricted Area - Within Downtown - Near Major Road - Development Policy Area - Near a Scenic Route - Gas Pipeline - Near a Park - Arena Policy Parking Area - Near a College - Near other Jurisdiction - Near State Corridor - Near a State Highway - Near Arena - Reid-Hillview ALUC - Water Company - Near Heavy Rail - Additional Inspections - Not used in Building folders Address Requested - For IR folder only. Change or add address Other - ???? # of Stories - Number of stories Building Type - Usedin Information Request folder only. Major use of building Total Building Area - Total Building Area Basement Stories - Number of stories in basement of the building # of Area Separation Walls - Number of area separation walls per California Building Code Section 504.6 Sprinklers Utilized for (1hr,area,story) - Sprinkler substitution for either one-hour rated construction, area separation walls or story increase Building Height - Height of the building as defined in California Building Code Section 209 FAR (w/o Garage) - Floor Area Ratio per City of San Jose Ordinance Sprinkler System Type - Sprinkler systems permitted to be use in San Jose Alarm System Type - Type of alarm system Emergency Electric System - Type of emergency power system # of Side Yards > 20' - Number of side yards that is wider than 20 feet Dimension > 20' - ???? Area Increase for Side Yards? - Yes if there is any sideyards used in the building area increase Easements used for allowable area - Yes if there is any easements used to calculate the building allowable area Calculated Allowable Area - Allowable area calculated per UBC Section 504 Calculated Occupant Load - Occupant load calculated per UBC Section 1003.2.2 Building (Complete) - Grants 100% permit approval Building (Fnd/Comp) - Allows a 10% foundation or 100% permit approval Building (Fnd/Struct/Shell/Comp) - Allows a 10% foundation, 30% structure, 80% shell, or 100% complete permit approval Electrical (Complete) - Grants 100% complete permit approval Electrical (Fnd/Comp) - Allows a 10% foundation or 100% complete permit approval Electrical (Fnd/Shell/Comp) - Allows a 10% foundation , 80% shell, 100% complete permit approval Mechanical (Complete) - Grants 100% complete permit approval Mechanical (Fnd/Comp) - Allows a 10% foundation or 100% permit approval Mechanical (Fnd/Shell/Comp) - Allows a 10%, 80% shell or 100% complete permit approval Plumbing (Complete) - Grants 100% permit approval Plumbing (Fnd/Comp) - Allows a 10% foundation, or 100% complete permit approval Plumbing (Fnd/Shell/Comp) - Allows a 10% foundation, 80% shell or 100% foundation permit approval Building (Fnd/Struct/Comp) - Allows a 10% foundation, 30% structure or 100% shell permit approval Permit Card Style - Single trade for single trade approvals. Multiple trades for combinations Code Edition UBC, UMC, UPC, UCBC - Current adopted editions of Uniform Building Code, Uniform Code for Building Conservation,Uniform Mechanical Code and Uniform Plumbing Code Code Edition NEC - Current adopted edition of National Electrical Code Code Edition Energy - Current adopted edition of energy regulations Code Edition Accessibility - Current adopted edition of disable access regulations New Use (Issue C of O)? - New Use (Issue C of O) – Yes will add issue Certificate of Occupancy inspection process Hours Billed - Hours billed # of Plan Pages Copied - Number of archived plan pages copied Report Cost - For Information Request folder only, Cost of Report # Document Pages copied - Number of pages of archived document copied # of Pages - For Information Request folder only, Number of pages Type of Construction - Type of Construction per 2001 California Building Code Section xxxx.xx.xx # Units Being Permitted - # Units Being permitted – value is used to calculate applicable permit issuance fees, energy fees, Construction taxes, Residential taxes # Dwelling Units Removed - Number of dwelling units removed # Dwelling Units Added - Number of dwelling units added Dwelling Occupancy Group - Dwelling Occupancy Groups per California Building Code Section 310 Stories - Stories – Value will add ICBO use modifier for building over 3 stories Sprinklers? - Sprinklers – Yes will add sprinkler modifier to ICBO use valuations Conditioned? - Conditioned – Yes will add conditioned modifier to ICBO use valuation and add energy plan modifier to plan check fee Shell Only? - Shell only – yes will make an 20% adjustment in the ICBO calculated valuation Mini-warehouse? - Mini-warehouse Type of House Move? - The house is moved into, out of or within the city limit of San Jose House move out of San Jose? - Infofield not used House move within San Jose? - Infofield not used # Bathrooms - Number of bathrooms # Bedrooms - Number of bedrooms # Bathrooms added - Number of bathrooms added # Bedrooms added - Number of bedrooms added Parking Occupancy Group - For residential projects only, parking occupancy group per California Building Code Section Table 3-A requirements Parking type of construction - For residential projects only, parking type of construction per California Building Code Chapter 6 requirements Existing Occupancy Group - Existing occupancy group based on California Building Code Chapter 3 Proposed Occupancy Group - Proposed occupancy group based on California Building Code Chapter 3 1 Model/Building # - Identification of model or building 1 # of 1 Model/Building - Number of buildings or models that have identification 1 2 Model/Building # - Identification of model or building 2 # of 2 Model/Building - Number of buildings or models that have identification 2 3 Model/Building # - Identification of model or building 3 # of 3 Model/Building - Number of buildings or models that have identification 3 4 Model/Building # - Identification of model or building 4 # of 4 Model/Building - Number of buildings or models that have identification 4 5 Model/Building # - Identification of model or building 5 # of 5 Model/Building - Number of buildings or models that have identification 5 6 Model/Building # - Identification of model or building 6 # of 6 Model/Building - Number of buildings or models that have identification 6 7 Model/Building # - Identification of model or building 7 # of 7 Model/Building - Number of buildings or models that have identification 7 8 Model/Building # - Identification of model or building 8 # of 8 Model/Building - Number of buildings or models that have identification 8 9 Model/Building # - Identification of model or building 9 # of 9 Model/Building - Number of buildings or models that have identification 9 10 Model/Building # - Identification of model or building 10 # of 10 Model/Building - Number of buildings or models that have identification 10 11 Model/Building # - Identification of model or building 11 # of 11 Model/Building - Number of buildings or models that have identification 11 12 Model/Building # - Identification of model or building 12 # of 12 Model/Building - Number of buildings or models that have identification 12 13 Model/Building # - Identification of model or building 13 # of 13 Model/Building - Number of buildings or models that have identification 13 14 Model/Building # - Identification of model or building 14 # of 14 Model/Building - Number of buildings or models that have identification 14 15 Model/Building # - Identification of model or building 15 # of 15 Model/Building - Number of buildings or models that have identification 15 16 Model/Building # - Identification of model or building 16 # of 16 Model/Building - Number of buildings or models that have identification 16 17 Model/Building # - Identification of model or building 17 # of 17 Model/Building - Number of buildings or models that have identification 17 18 Model/Building # - Identification of model or building 18 # of 18 Model/Building - Number of buildings or models that have identification 18 19 Model/Building # - Identification of model or building 19 # of 19 Model/Building - Number of buildings or models that have identification 19 20 Model/Building # - Identification of model or building 20 # of 20 Model/Building - Number of buildings or models that have identification 20 Sq Ft of Projected Roof Area - Number of square feet of projected roof area Are Copies Needed? - For Information folder only, yes if copies are needed? Job Under Construction? - For Information folder only, yes if the job under construction? Soil Profile Type - Soil profile type based on California Building Code Table 16-J Distance to Type A fault - Distance to Type B fault based on California Building Code Table 16-S and 16-T requirements Distance to Type B fault - Distance to Type B fault based on California Building Code Table 16-S and 16-T requirements Seismic Upgrade? - Yes if it si a seismic upgrade project? Slope > 20%? - Is the site slope greater than 20% per California Building Code Section 1806.5 Foundation Design - Type of foundation design 1 Lateral System Type - Type of foundation based on California Building Code Table 16-N 2 Lateral System Type - Type of foundation based on California Building Code Table 16-N 3 Lateral System Type - Type of foundation based on California Building Code Table 16-N 4 Lateral System Type - Type of foundation based on California Building Code Table 16-N 5 Lateral System Type - Type of foundation based on California Building Code Table 16-N Solar Installation Valuation - Cost of installation of solar energy panels Repair % of Valuation - Percentage of valuation designated to repair versus total valuation Solar Installation - Installation of solar energy panels City Owned Property - City Owned Buildings – Yes enacts exemption Percent very low income - % of Low Income - % determines amount to be exempted Very Low Income Housing? - Very Low Income Housing – Yes enacts exemption Church Owned? - Church Owned – Yes enacts exemption Bld Leased to County of Santa Clara? - Bldg Leased to County of Santa Clara – Yes enacts exemption Federal Government Financing? - Federal Government Financing – Yes enacts exemption Substandard Housing Rehabilitation? - Substandard Housing Rehabilitation – Yes enacts exemption Repair/Reconstruction? - If repair and reconstruction project, development tax is exempted Evergreen Incentive Zone - Evergreen Incentive Zone - Yes enacts exemption. For Tract, multi-family and single family folder only. Expired on 01/01/2003 Enterprise Zone Target Area - For commercial, industrial and multifamily folders only. No construction tax is collected if the project is located in this zone. Expired on ??/??/???? Industrial Designation - Yes if the building is qualified for the industrial designation per Building Division policy Substandard Housing Loan Amount - Substandard Loan Amount – Value determines amount to be exempted TI Special Incentive? - Is the project designated as Special Incentive Tenant Improvement program per Building Division policy no. xxxx.xx.xx? If yes, development tax is deferred. Retrieve All Documents? - Yes if all documents are to be retrieved Retrieve Building Plan Sets? - Yes if building plan sets are to be retrieved Building Plan Pages/DocID - For Information Request folder only, building plan pages or doucment ID Electrical Plan Pages/DocID - For Information Request folder only, electrical plan pages or doucment ID Plumbing Plan Pages/DocID - For Information Request folder only, plumbing plan pages or doucment ID Mechanical Plan Pages/DocID - For Information Request folder only, mechanical plan pages or doucment ID Structural Calc Pages/DocID - For Information Request folder only, structural calculation pages or doucment ID Soils Report Pages/DocID - For Information Request folder only, soil report pages or doucment ID Permit not Final-Request Inspection Docs - For Information Request folder only, Yes if Permit not Final-Request Inspection Documents Specific Permit No. or Description - For Information Request folder only, Specific permit number or description All Electrical Permits? - For Information Request folder only, Yes to consider all electrical permits All Mechanical Permits? - For Information Request folder only, Yes to consider all mechanical permits All Plumbing Permits? - For Information Request folder only, Yes to consider all plumbing permits All Building Permits? - For Information Request folder only, Yes to consider all building permits All Permits Requested? - For Information Request folder only, Yes to consider all permits Other Pages/DocID - For Information Request folder only, other pages or document ID Retrieve Other - Retrieve Other Truss Calc Pages/DocID - - For Information Request folder only, Truss calculation pages or document ID Retrieve Truss Calculations? - Yes if Truss Calculations is retrieved Supporting Doc Pages/DocID - Support document pages or document ID Retrieve Supporting Documents? - For Information Request folder only, Yes to retrieve supporting documents Retrieve Soils Report? - For Information Request folder only, Yes to retrieve soils report Retrieve Structural Calculations? - For Information Request folder only, Yes to retrieve structural calculations Retrieve Mechanical Plan Sets? - Yes if mechanical plan sets are retrieved Retrieve Plumbing Plan Sets? - Yes if plumbing plan sets are retrieved Retrieve Electrical Plan Sets? - Yes if electrical plan sets are retrieved All Document Pages/DocID - All Document Pages/DocID Fire Suppression Sys. Permit Required? - Yes if fire suppression system permit is required Fire Alarm System Permit Required? - Yes if fire alarm system permit is required Sprinkler Monitoring Sys. Permit Req'd? - Yes if sprinkler system permit is required Fire Review Required? - Fire review required – Yes will add process and charge Plan check fees, No will delete process & Plan check fee Occupancy Identified is appropriate? - For Fire Department use, Yes if occupancy identified is appropriate # of Control Areas defined - For Fire Department use, number of control areas defined Hazardous Materials Sys. Permit Req'd? - For Fire Department use, Yes if hazardous materials system permit is required Hazardous Materials Inspection Req'd? - For Fire Department use, Yes if hazardous materials inspection is required HazMat Review Required? - Hazmat review required – Yes will add process and charge plan check fees, No will delete process & plan check fee Estimated Occupancy Date - Estimated occupancy date Box File # - For Information Request folder only, Box File # Box File # - For Information Request folder only, Box File # Box File # - For Information Request folder only, Box File # Box File # - For Information Request folder only, Box File # Box File # - For Information Request folder only, Box File # Combo Project Inspector - Name of project combination inspector Combo Count - Combo count Building Inspector - Name of building Inspector Electrical Inspector - Name of electrical Inspector Building Stop Work - Yes if building stop work Building Count - Building count Combo Stop Work - Yes if combo stop work Electrical Count - Electrical count Plumb/Mech Stop Work - Yes if plumbing / mechanical stop work Plumb/Mech Count - Mechanical plumbing count Plumb/Mech Inspector - Name of mechanical / plumbing inspector Electrical Stop Work - Yes if electrical stop work Permit Number (One Only/Request) - Are Plans Imaged? - Yes if plans are imaged California Contractors License Number - California Contractors License Number Copy Authorization REQUIRED - Yes if copy authorization is required RS Parking Type of Construction - Type of construction per California Building Code Chapter 6 on residential parking structure Simple Permit? - Yes if it is a simple permit # Lots/Buildings - Number of lots per building RS Parking Occupancy Group - Occupancy group per California Building Code Chapter 3 on residential parking structure DTS - Estimated Occupancy Date - DTS - Estimated Occupancy Date Gas Service Type - # of Gas Meters - Electrical Service Type - Wire Size - Main Switch Size - Voltage - Meter Type - Phase - Service Rating - # of Electrical Meters - Service Connection - Gas Pressure - # Water pollution Control plan sets - # Fire Plan Sets - Number of plan sets submitted for fire plan review Other Submittals - Other types of submittals ICBO/UL/WH Report # - Evaluation report number Evaluation Report Type - Evaluation service that create the report. Choose from International Conference off Building Officials, Underwriter Lab or Warnock Hersey # Soils Reports - Number of copies of soils report submitted for building plan review # Title 24 Energy forms - - Number of copies of Title 24 Energy forms submitted for building plan review # Structural Calculations - Number of structural calculations submitted for plan review # Building Plan Sets - Number of plan sets submitted for building plan review # Building Site Plan Sets - Number of builidng site plans submitted for building site plan review # Health Plan Sets - Number of Environment Health Department approved plans submitted for mechanical/plumbing plan review # Mechanical Plan Sets - Number of mechanical plans submitted for mechanical plan review # Plumbing Plan Sets - Number of plumbing plans submitted for plumbing plan review # Electrical Plan Sets - Number of electical plans submitted for electrical plan review # Electrical Site Plan Sets - Number of electrical site plans submitted for electrical site plan review # Plumbing Site Plan Sets - Number of plumbing site plans submitted for plumbing site plan review Traffic Noise Analysis - Number of traffic noise report submitted for review Building 1 Inspection - Electrical 1 Inspection - Mechanical 1 Inspection - Plumbing 1 Inspection - Building More Than 1 Inspection - Electrical more than 1 Inspection - Mechanical more than 1 Inspection - Plumbing more than 1 Inspection - Plumbing Use Building Area - For multi-family with a work proposed of new construction and move, answer yes will utilize the square footage associated with the dwelling area infofield in square feet plus selected uses and square footage listed for each use infofields for fee calculation. If work proposed is addition or alteration, answer yes will utilize the square footage associated with the floor area added infofield in square feet Mechanical Use Building Area - For commercial or industrial projects, answer yes will assess sub-trade fees associated with selected uses and the square footage listed for each use. For residential projects with a work proposed of new construction or move, answer yes will utilize the square footage associated with the dwelling area infofield in square feet for fee calculation. If work proposed is in addition or alteration, answer yes will utilize the square footage associated with the floor area added infofield in square feet Electrical Use Building Area - For commercial or industrial projects, answer yes will assess sub-trade fees associated with selected uses and the square footage listed for each use. For residential projects with a work proposed of new construction or move, answer yes will utilize the square footage associated with the dwelling area infofield in square feet for fee calculation. If work proposed is in addition or alteration, answer yes will utilize the square footage associated with the floor area added infofield in square feet P W Development Clearance Required? - Yes if Public Works Development Clearance is required Noise Analysis Review? - Yes if noise analysis review is required Plan Conformance Review? - Yes if planning conformance review is required Health Review? - Yes if health department review is required Zoning Review - Yes if zoning review is required Electrical Site Plan Review Required? - Yes if electrical site plan review is required 3rd Party Review Required? - Yes if the project is reviewed by a city approved third party building plan review company Mechanical Review Required? - Yes if mechanical plan review is required Plumbing Review Required? - Yes if plumbing plan review is required Electrical Review Required? - Yes if electrical review is required Building Review Required? - Yes if building plan review is required Planning Permit # - Yes if plumbing plan review is required Planning Adjustment Required? - Yes if planning adjustment review is required Minor Plan Review? - Yes will assess a ½-hour minimum plan check fee, i.e. overrides calculated plan check fee for all trades Special Tracking? - For in house use only, to specify the type of tracking Plumbing Site Plan Review Required? - Yes if plumbing site plan review is required Water Pollution Control Review? - Yes if Water Pollution Control review is required Roof Class Required - The classification by Section 1504 assigned to a roof covering or roofing assembly PW File # - Public Works Department file number Roof System Fire Classification - The classification by California Building Code Section 1504 assigned to a roof covering or roofing assembly # of Squares - A square is 100 square feet of roof surface Roof Slope - Slope of the roof Weight of Existing Roof to Remain - Total weight of existing roof system to remain Maximum Span - The span length from two supports Rafter Size/Spacing - Size and spacing of roof rafters Gravel LB/Square - For gravel roof only, the weight of gravel roofing per 100 square feet CapSheet LB/Square - The weight per 100 square feet of roof covering coated both side with a bituminous compound and surfaced with mineral granules, mica, talc, ilmenite, inorganic fibers or similar materials Roof Ply LB/Square - The weight per 100 square feet of roof felt # Roof Plys - Number of layer of felt in built-up roofing Built-Up Roof Base sheet - A product used as the base ply in a built-up roofing membrane Interlayment - A layer of felt or non-bituminous saturated felt not less than 18 inches wide, shingled between each course of roofing materials Underlayment - One or more layers of felt, shealthing paper, non-bituminous saturated felt or other approved material over which a roofing system New Roof Materials Type - Material type of the roof covering used for replacement Sheathing Added? - Is shealthing added to the roof? Roof Slope Altered? - Is the slope of the roof altered? # Existing Roof Covers to Remain - Number of existing roof covering to remain Existing Roof Materials Type - Existing material type of the roof covering used Exposure - Maximum weather exposure based on CBC Table 15C Installed Weight of New Roofing System - Total weight of new roof system to install Roof System Manufacturer - - Name of the roof system manufacturer Lot Size - Size of the lot where the property is located Front Easement - Number of feet of front easement Rear Easement - Number of feet of rear easement Right Easement - Number of feet of right easement Other Easement - Number of feet of other easement Left Easement - Number of feet of left easement Roof Alteration 1 - Type of skylight installed. See fee schedule for details Roof Alteration 2 - Type of skylight installed. See fee schedule for details Roof Alteration 3 - Type of skylight installed. See fee schedule for details Roof Alteration 4 - Type of skylight installed. See fee schedule for details Roof Alteration 5 - Type of skylight installed. See fee schedule for details Roof Alteration 6 - Type of skylight installed. See fee schedule for details Alteration 1 - A pick list of alteration elements utilized in residential folders that have associated square footage costs or flat rate fees Sq Ft Alteration 1 - Associated sq. ft. of selected item # Alterations 1 - # Alterations – This value is a multiplier of the listed flat fee or the product of the alteration times the sq. ft. value Alteration 2 - Sq Ft Alteration 2 - # Alterations 2 - Alteration 3 - Sq Ft Alteration 3 - # Alterations 3 - Alteration 4 - Sq Ft Alteration 4 - # Alterations 4 - Alteration 5 - Sq Ft Alteration 5 - # Alterations 5 - Alteration 6 - Sq Ft Alteration 6 - # Alterations 6 - Alteration 7 - Sq Ft Alteration 7 - # Alterations 7 - Alteration 8 - Sq Ft Alteration 8 - # Alterations 8 - Alteration 9 - Sq Ft Alteration 9 - # Alterations 9 - Alteration 10 - Sq Ft Alteration 10 - # Alterations 10 - CI Alteration 1 - A pick list of comercial industrial alteration elements that have associated unit costs or flat rate fees CI Sq Ft Alteration 1 - Associated square footage of selected item # CI Alterations 1 - This value is a multiplier of the listed flat fee or the product of the alteration times the square feet CI Alteration 2 - CI Sq Ft Alteration 2 - # CI Alterations 2 - CI Alteration 3 - CI Sq Ft Alteration 3 - # CI Alterations 3 - CI Alteration 4 - CI Sq Ft Alteration 4 - # CI Alterations 4 - Accessory/Site 1 - A pick list of accessory elements that have associated square footage costs or flat rate fees Sq Ft Accessory/Site 1 - Associated square footage of selected item # Accessory/Site 1 - The value of this info field is a multiplier of the listed flat fee or the product of the alteration times the sq. ft. value. Accessory/Site 2 - Sq Ft Accessory/Site 2 - # Accessory/Site 2 - Accessory/Site 3 - Sq Ft Accessory/Site 3 - # Accessory/Site 3 - Accessory/Site 4 - Sq Ft Accessory/Site 4 - # Accessory/Site 4 - Accessory/Site 5 - Sq Ft Accessory/Site 5 - # Accessory/Site 5 - Accessory/Site 6 - Sq Ft Accessory/Site 6 - # Accessory/Site 6 - Other - Other uses or accessories not listed on the picklist for valuation purpose Valuation of Other - The valuation for an unlisted element Other2> - Other uses or accessories not listed on the picklist for valuation purpose Valuation of Other2 - The valuation for an unlisted element ReRoof Valuation - Valuation for the reroof project MF Garage 1 Type - Assesses the valuation of garages used solely for residential use. The listings are already adjusted with the ICBO modifiers for mechanical and sprinklers and do not have any regional modifies applied. These uses are also exempt from Construction Tax per the Municipal ordinance MF Garage 1 Sq Ft - The area associated with multifamily garage MF Garage 2 Type - Assesses the valuation of garages used solely for residential use. The listings are already adjusted with the ICBO modifiers for mechanical and sprinklers and do not have any regional modifies applied. These uses are also exempt from Construction Tax per the Municipal ordinance MF Garage 2 Sq Ft - The area associated with multifamily garage Use 1 - A pick list of commercial or industrial uses Use 1 Type - A picklist to choose from New Construction, Interior Finish and Tenant Improvement Use 1 Sq Ft - Area in square feet of associated use Use 1 Construction Type - A picklist from ICBO California Building Code Table 6-A for selected use Use 1 Occupancy Groups - Occupancy group classification per California Building Code Table 3-A for commercial industrial projects Use 2 - Use 2 Type - Use 2 Sq Ft - Use 2 Construction Type - Use 2 Occupancy Groups - Use 3 - Use 3 Type - Use 3 Sq Ft - Use 3 Construction Type - Use 3 Occupancy Groups - Use 4 - Use 4 Type - Use 4 Sq Ft - Use 4 Construction Type - Use 4 Occupancy Groups - Use 5 - Use 5 Type - Use 5 Sq Ft - Use 5 Construction Type - Use 5 Occupancy Groups - Use 6 - Use 6 Type - Use 6 Sq Ft - Use 6 Construction Type - Use 6 Occupancy Groups - Use 7 - Use 7 Type - Use 7 Sq Ft - Use 7 Construction Type - Use 7 Occupancy Groups - Use 8 - Use 8 Type - Use 8 Sq Ft - Use 8 Construction Type - Use 8 Occupancy Groups - Use 9 - Use 9 Type - Use 9 Sq Ft - Use 9 Construction Type - Use 9 Occupancy Groups - Use 10 - Use 10 Type - Use 10 Sq Ft - Use 10 Construction Type - Use 10 Occupancy Groups - Total Building Area - MF Amenity 1 - A pick list of multifamily building enhancement features that is used to adjust the total valuation of the new residential construction valuation MF Amenity 1 Sq Ft - MF Amenity 2 - MF Amenity 2 Sq Ft - MF Amenity 3 - MF Amenity 3 Sq Ft - MF Amenity 4 - MF Amenity 4 Sq Ft - MF Amenity 5 - MF Amenity 5 Sq Ft - MF Amenity 6 - MF Amenity 6 Sq Ft - MF Amenity 7 - MF Amenity 7 Sq Ft - MF Amenity 8 - MF Amenity 8 Sq Ft - MF Amenity 9 - MF Amenity 9 Sq Ft - MF Amenity 10 - MF Amenity 10 Sq Ft - CDDD Project Total Sq Ft - Calculate CDDD Deposit? - Quantity - Square Foot - Garage/Shed/Carport type - Swimming Pool/Spa - Skylights - Screen Room - Retaining Wall - Patio Cover type - Fireplace - Fence type - Awning type - Antenna type - Dwelling Sq Ft - The value is used to assesses new residential construction valuation based on ICBO valuation Area of Existing Bldg (inc att garage) - Utilized to list the total existing square footage of the building being altered. This infofield is utilized in conjunction with infofield ‘Floor Area Added’ to determine if Commercial Residential Mobile home Park (CRMP) tax is assessed in residential folders Demolition Sq Ft - Area of demolition Floor Area Added Sq Ft - This infofield is utilized to calculated sub-trade fees for residential additions, CRMP Tax and Construction Tax applicablity RS Amenity 1 - A pick list of single family residential building enhancement features that is used to adjust the total valuation of the new residential construction valuation RS Amenity 1 Sq Ft - The square footage assoicated with the enhancement feature RS Amenity 2 - A pick list of single family residential building enhancement features that is used to adjust the total valuation of the new residential construction valuation RS Amenity 2 Sq Ft - The square footage assoicated with the enhancement feature RS Amenity 3 - A pick list of single family residential building enhancement features that is used to adjust the total valuation of the new residential construction valuation RS Amenity 3 Sq Ft - The square footage assoicated with the enhancement feature RS Amenity 4 - A pick list of single family residential building enhancement features that is used to adjust the total valuation of the new residential construction valuation RS Amenity 4 Sq Ft - The square footage assoicated with the enhancement feature RS Amenity 5 - A pick list of single family residential building enhancement features that is used to adjust the total valuation of the new residential construction valuation RS Amenity 5 Sq Ft - The square footage assoicated with the enhancement feature RS Amenity 6 - A pick list of single family residential building enhancement features that is used to adjust the total valuation of the new residential construction valuation RS Amenity 6 Sq Ft - The square footage assoicated with the enhancement feature RS Garage 1 Type - A pick list of single family residential garage types. The distinction between attached and detached is made to facilitate the CRMP tax exemption that exists in the municipal ordinance for accessory structures RS Garage 1 Sq Ft - The square footage associated with the residential garage type RS Garage 2 Type - A pick list of single family residential garage types. The distinction between attached and detached is made to facilitate the CRMP tax exemption that exists in the municipal ordinance for accessory structures RS Garage 2 Sq Ft - The square footage associated with the residential garage type MF Garage Occupancy - Occupancy group classification per California Building Code Chapter 3 for multifamily projects MF Garage Construction Type - Type of Construction per California Building Code Chapter 6 for multifamily projects Fee Estimate? - Yes will determine this folder being an estimate folder Smoke Control System - Unreasonable Hardship? - Yes to indicate this project is requested to have unreasonble hardship consideration # of Parking Spaces - Number of parking spaces Req'd # Accessible Parking Spaces - Number of required disabled access parking spaces High Rise? - Yes to indicate the project is a high rise building per California Building Code Section 209 Alternate Materials Request 1 - Not used Alternate Materials Request 2 - Not used Alternate Materials Request 3 - Not used Alternate Materials Request 4 - Not used Alternate Materials Request 5 - Not used Alternate Materials Request 6 - Not used Alternate Materials Request 7 - Not used Alternate Materials Request 8 - Not used Alternate Materials Request 9 - Not used Alternate Materials Request 10 - Not used Submitted Valuation (initial) - Project valuation when application is first submitted Permit Valuation - The valuation utilized to calculate the permit being issued, i.e. 10%, 30%, 40%, 70%, 80%, 90% or 100%. The valuation listed will be the greater of the contract valuation or the City Calculated Valuation unless use contract valuation = yes and that value is less than the City Calculated valuation. Contract Valuation - Valuation listed on contract or architectural detail estimate Use Contract Value - Yes will insert contract value into permit valuation infofield City Calculated Valuation The total valuation derived from all entry listed above except contract valuation Revised Valuation - Revised valuation Project Valuation - The total valuation for 100% completion of the project California Contractors License Type - A picklist of the California contractor license classification Plan Check Category - Category of plan check for internal use only Major Use - A picklist of major use of building or space Work Proposed - A picklist of work proposed
200 East Santa Clara Street, San Jose CA 95113-1905 The City of San José On-Line Permits website is developed by Intergraph Corporation.